Calibration





CALIBRATION OF OTHER INSTRUMENTS: PIPETTES


  CALIBRATION OF OTHER INSTRUMENTS: PIPETTES
 
Calibration service of pipettes (or microdosers), performed with LAT certified instrumentation (or equivalent in EA). Possibility to perform the service also at the location agreed with the customer or at our laboratory.

PIPETTES

  • Calibration of fixed- or variable-volume, single- or multichannel pipettes and micropipettes in accordance with ISO 8655.
  • Procedure: Preventive maintenance (on request). Measurements performed on 3 points (variable volume). First measurement 3*10 or 2*4 (“As found” calibration). Further measurement 3*10 (“As left” calibration). Release of calibration report.

    Calibration service time: 10 days from receipt of order.
AVAILABLE VERSIONS
 CodeDescription
CPI01 Cost-effective calibration of fixed-volume single-channel pipettes. Measurements carried out with 4 "As left" dosages, with issue of calibration report. Calibration service time: 10 days.
CPI02 Full calibration of fixed-volume single-channel pipettes in accordance with ISO 8655. Measurements carried out with 10 "As left" dosages, with issue of calibration report. Calibration service time: 10 days.
CPI03 Full GLP/GMP calibration of single-channel fixed-volume pipettes in accordance with ISO 8655. Measurements performed with 10 "As found" and 10 "As left" dosages, with issue of double calibration report. Calibration service time: 10 days.
CPI04 Cost-effective calibration of variable-volume single-channel pipettes. Measurements carried out on 3 volumes with 4 "As left" dosages, with issue of calibration report. Calibration service time: 10 days.
CPI05 Full calibration of variable-volume single-channel pipettes in accordance with ISO 8655. Measurements carried out on 3 volumes with 10 "As left" dosages, with issue of calibration report. Calibration service time: 10 days.
CPI06 Full GLP/GMP calibration of variable-volume single-channel pipettes in accordance with ISO 8655. Measurements carried out on 3 volumes with 10 "As found" and 10 "As left" dosages, with issue of a double calibration report. Calibration service time: 10 days.
CPM01 Cost-effective calibration of fixed-volume multichannel pipettes. Measurements carried out with 4 "As left" dosages for each channel, with issue of calibration report. Calibration service time: 10 days.
CPM02 Full calibration of fixed-volume multichannel pipettes in accordance with ISO 8655. Measurements carried out with 10 "As left" dosages for each channel, with issue of calibration report. Calibration service time: 10 days.
CPM03 Full GLP/GMP calibration of fixed-volume multichannel pipettes in accordance with ISO 8655. Measurements carried out with 10 "As found" and 10 "As left" dosages for each channel, with issue of a double calibration report. Calibration service time: 10 days.
CPM04 Cost-effective calibration of variable-volume multichannel pipettes. Measurements carried out on 3 volumes with 4 "As left" dosages for each channel, with issue of calibration report. Calibration service time: 10 days.
CPM05 Full calibration of variable-volume multichannel pipettes in accordance with ISO 8655. Measurements performed on 3 volumes with 10 "As left" dosages for each channel, with issue of calibration report. Calibration service time: 10 days
CPM06 Full GLP/GMP calibration of variable-volume multi-channel pipettes in accordance with ISO 8655. Measurements carried out on 3 volumes with 10 "As found" and 10 "As left" dosages for each channel, with issue of a double calibration report. Calibration service time: 10 days.
PIPETTE MAINTENANCE
 CodeDescription
MANP Pipette preventive maintenance, including greasing and replacement of parts subject to wear with original spare parts.

All the specifications and images can be subject to variations and upgrades without prior notice.